Spray Mop Tank Size Guide — 225, 570 and 1000 ml, Iron vs Aluminium Pole
How do I choose a tank size from the floor area I clean?
Match the bottle to the walk to the tap. A 225 ml body suits spot work and small rooms; 570 ml covers about 25 m², roughly a kitchen and a hallway; 1000 ml covers about 45 m², a whole flat in one fill. Above that, the answer is a spare bottle, not a bigger tank.
| Capacity | About how much floor | Who it suits |
|---|---|---|
| 225 ml | Spot work, bathrooms, small rooms | Compact body, low retail tier |
| 290–430 ml | One room per fill | Entry and mid retail tiers |
| 550–700 ml | About 25 m² at 570 ml | Mainstream home, wide 41.5 × 14 cm head |
| 1000 ml | About 45 m² | Large home, light commercial |
| 2 × 330 ml | Same floor, water kept separate | Clean and dirty water in two chambers |
| 350 ml electrolyzed | One room per fill | Disinfecting without a chemical refill |
Capacities and pad sizes for every body are on the product range; the dual-chamber version has its own page at SM1026.
Is a bigger tank always better?
No. A full 1000 ml bottle adds about a kilogram to the head end of the pole, and that weight is carried on one wrist for the whole floor. A larger tank also moves the product into a higher retail tier, where the buyer expects a wider head and a stronger pole to go with it — so tank, head width and pole gauge should be chosen together.
Our wide-head bodies pair a 41.5 × 14 cm pad with a 25 mm pole; the narrower 39.5 × 12 cm bodies run a 22 mm pole. That pairing is not cosmetic: it is the point at which the assembly still passes the pole-stiffness test with a full bottle fitted.
What is the real capacity behind a nominal figure?
The nominal figure is a mould cavity, not a guarantee. On a measured production sample a body specified at 300 ml filled to 301.8 ml, which is 0.6 % above nominal — the sort of tolerance a buyer should expect, and the reason a purchase order should state both the nominal capacity and the acceptable range rather than the nominal alone.
We publish the measured value rather than the catalogue value because a 0.6 % oversize is a selling point and a 5 % undersize is a returns problem, and the two are indistinguishable until someone fills a bottle and weighs it.
Iron or aluminium pole — which lasts longer?
Aluminium is lighter and does not rust when the coating is breached; iron is stiffer and cheaper, and it fails by rusting from the inside once water gets past a scratch. Both are offered in one, two and three sections. On a measured pole we run 22.07 mm diameter, a 0.510 mm wall and 1,135 mm length, holding 70 N for 10 seconds.
| Iron | Aluminium | |
|---|---|---|
| Weight | Heavier — more effort per stroke | Lighter — easier on the wrist |
| Stiffness | Higher for the same wall | Lower, so the wall is usually thicker |
| Failure mode | Rust from inside a scratch | Dents rather than rusts |
| Best for | Price-led programmes, dry climates | Wet rooms, coastal markets, premium tier |
Both pass the same stiffness test at 5 kg for 3 minutes with a 5 mm deflection limit; the difference is how they age, not whether they hold up on day one.
How many units fit in a container?
It depends on the body and the packing, not on the tank alone. As a worked example, the 1000 ml flagship loads about 2,460 pieces in a 20 foot container, 5,112 in a 40 foot and 6,000 in a 40HQ. Every other model is confirmed per order, because carton size changes with the head width and the packing format.
Trade terms, MOQ and container quantities are set out on the wholesale terms page; the HS code for the category is 9603.90.9090, and the import reference covers the national suffixes.
Which tank should a private-label programme start with?
Start in the middle and add a second body rather than stretching one. A 550–700 ml wide-head body covers the mainstream claim, a 1000 ml body covers the large-floor claim, and a 2 × 330 ml body covers the clean-and-dirty claim; three bodies cover three shelf stories without a new mould for each.
Tooling for a new body takes 45–55 days; colour, printing and packing do not. That is why most programmes customise the bottle colour and the card first and open a mould second — see OEM and private label.
FAQ
What tank size do most homes need?
Between 550 and 700 ml. It covers a normal flat in one fill without adding a kilogram of water to the head end, which is the compromise most buyers settle on.
Does a bigger tank mean fewer refills?
Yes, in proportion: about 25 m² at 570 ml against about 45 m² at 1000 ml on a smooth sealed floor. On a rough floor both figures fall, because more passes means more sprays.
Is a dual-tank mop worth it?
It is worth it when the complaint is dirty water being pushed back onto the floor. Two chambers keep the rinse water separate, at the cost of a heavier body and a higher retail tier — a feature claim rather than a cleaning-power claim.
Can the pole be swapped on an existing body?
Usually yes within the same body family, because the pole thread and the collar are shared. Confirm the gauge with the body: the wide-head bodies are built around a 25 mm pole and the narrower ones around 22 mm.